
- Soort product
- Ringkerntransformator101Bevestigingsschijven5
- Merk
- BLOCK54Sedlbauer40Talema12
- VerkoperConrad Electronic SE
- Prijs
- Uitgangsstroom
- 0.25 A10.42 A20.50 A10.625 A11 A11.04 A21.25 A41.31 A11.33 A11.39 A11.67 A32 A12.08 A32.18 A12.22 A12.28 A12.5 A12.66 A12.67 A22.72 A12.78 A33.33 A63.75 A13.83 A14.17 A34.35 A14.44 A15 A45.00 A15.22 A15.33 A15.55 A15.56 A16.25 A26.66 A26.67 A26.95 A27.14 A17.67 A18.33 A68.69 A19.16 A19.37 A19.58 A110 A210.4 A110.40 A110.42 A112.50 A113.04 A113.88 A1417 mA1500 mA1555 mA1833 mA2
- Vermogen
- 15 VA620 VA230 VA940 VA450 VA1060 VA280 VA7100 VA8120 VA7160 VA8200 VA2225 VA4230 VA3250 VA2300 VA9330 VA1400 VA3500 VA5625 VA2800 VA11000 VA21200 VA11600 VA12000 VA13000 VA1
- Uitgangsspanning
- 6 V/AC49 V/AC511.50 V/AC112 V/AC1912 V415 V/AC615 V318 V/AC1418 V222 V324 V/AC1530 V/AC1235 V/AC240 V/AC145 V/AC150 V/AC1115 V/AC8
- Aansluiting
- Ingangsspanning
- Aantal uitgangen
- Certificaten
- Aanbiedingen & overig
Ringkerntransformatoren
106 resultaten

Sedlbauer 858739 Ringkerntransformator 1 x 230 V 2 x 12 V/AC 300 VA 12.50 A

Sedlbauer 858251 Ringkerntransformator 1 x 230 V 2 x 12 V/AC 15 VA 0.625 A

Sedlbauer 859729 Ringkerntransformator 1 x 230 V 2 x 12 V/AC 30 VA 1.25 A

Sedlbauer 858 258 Ringkerntransformator 1 x 230 V 2 x 12 V/AC 160 VA 6.67 A

Sedlbauer 859730 Ringkerntransformator 1 x 230 V 2 x 12 V/AC 80 VA 3.33 A

BLOCK RKD 400/2x24 Ringkerntransformator 2 x 115 V 2 x 24 V/AC 400 VA 8.33 A

Sedlbauer 859774 Ringkerntransformator 1 x 230 V 2 x 15 V/AC 230 VA 7.67 A

Sedlbauer 858743 Ringkerntransformator 1 x 230 V 2 x 30 V/AC 15 VA 0.25 A

BLOCK RTE 40/2x24 Ringkerntransformator 40 VA 833 mA

Sedlbauer 859770 Ringkerntransformator 1 x 230 V 2 x 30 V/AC 30 VA 0.50 A

Sedlbauer 825013 Ringkerntransformator 1 x 230 V 2 x 9 V/AC 50 VA 2.78 A

Sedlbauer 858252 Ringkerntransformator 1 x 230 V 2 x 12 V/AC 50 VA 2.08 A

BLOCK RTE 160/2x15 Ringkerntransformator 160 VA 5.33 A

Talema 19272-P1S02 Ringkerntransformator 1 x 230 V 2 x 15 V 80 VA

Sedlbauer 825004 Ringkerntransformator 1 x 230 V 2 x 18 V/AC 15 VA 0.42 A

BLOCK RKD 400/2x30 Ringkerntransformator 2 x 115 V 2 x 30 V/AC 400 VA 6.66 A

Sedlbauer 859776 Ringkerntransformator 1 x 230 V 2 x 30 V/AC 230 VA 3.83 A

BLOCK RTE 50/2x24 Ringkerntransformator 50 VA 1.04 A

Talema 19252-P1S02 Ringkerntransformator 1 x 230 V 2 x 15 V 30 VA

Talema 19254-P1S02 Ringkerntransformator 1 x 230 V 2 x 22 V 30 VA

Talema 19253-P1S02 Ringkerntransformator 1 x 230 V 2 x 18 V 30 VA

BLOCK RKD 160/2x35 Ringkerntransformator 2 x 115 V 2 x 35 V/AC 160 VA 2.28 A

Talema 19271-P1S02 Ringkerntransformator 1 x 230 V 2 x 12 V 80 VA

BLOCK RTE 80/2x15 Ringkerntransformator 80 VA 2.67 A

Sedlbauer 825061 Ringkerntransformator 2 x 115 V 2 x 115 V/AC 500 VA 2.18 A

Bevestigingsschijven 90 mm 530 215 Sedlbauer

BLOCK RKD 1600/2x115 Ringkerntransformator 2 x 115 V 2 x 115 V/AC 1600 VA 6.95 A

BLOCK RKD 3000/2x115 Ringkerntransformator 2 x 115 V 2 x 115 V/AC 3000 VA 13.04 A

BLOCK RKD 625/2x115 Ringkerntransformator 2 x 115 V 2 x 115 V/AC 625 VA 2.72 A

BLOCK RTE 200/2x12 Ringkerntransformator 200 VA 8.33 A

Bevestigingsschijven 110 mm 530 216 Sedlbauer

Sedlbauer 859780 Ringkerntransformator 1 x 230 V 2 x 18 V/AC 500 VA 13.88 A

BLOCK RKD 50/2x12 Ringkerntransformator 2 x 115 V 2 x 12 V/AC 50 VA 2.08 A

Bevestigingsschijven 50 mm 531707 Sedlbauer

Sedlbauer 858740 Ringkerntransformator 1 x 230 V 2 x 18 V/AC 300 VA 8.33 A

Sedlbauer 859732 Ringkerntransformator 1 x 230 V 2 x 12 V/AC 230 VA 9.58 A

BLOCK RKD 50/2x24 Ringkerntransformator 2 x 115 V 2 x 24 V/AC 50 VA 1.04 A

BLOCK RKD 225/2x12 Ringkerntransformator 2 x 115 V 2 x 12 V/AC 225 VA 9.37 A

BLOCK RKD 1000/2x50 Ringkerntransformator 2 x 115 V 2 x 50 V/AC 1000 VA 10 A

BLOCK RKD 40/2x6 Ringkerntransformator 2 x 115 V 2 x 6 V/AC 40 VA 3.33 A

Sedlbauer 825026 Ringkerntransformator 1 x 230 V 2 x 12 V/AC 100 VA 4.17 A

BLOCK RKD 225/2x30 Ringkerntransformator 2 x 115 V 2 x 30 V/AC 225 VA 3.75 A

BLOCK RKD 30/2x18 Ringkerntransformator 2 x 115 V 2 x 18 V/AC 30 VA 833 mA

Talema 19301-P1S02 Ringkerntransformator 1 x 230 V 2 x 12 V 225 VA
Talema 19263-P1S02 Ringkerntransformator 1 x 230 V 2 x 18 V 50 VA

Talema 19304-P1S02 Ringkerntransformator 1 x 230 V 2 x 22 V 225 VA

BLOCK RKD 330/2x18 Ringkerntransformator 2 x 115 V 2 x 18 V/AC 330 VA 9.16 A

BLOCK RKD 1200/2x115 Ringkerntransformator 2 x 115 V 2 x 115 V/AC 1200 VA 5.22 A

BLOCK RKD 625/2x30 Ringkerntransformator 2 x 115 V 2 x 30 V/AC 625 VA 10.42 A

BLOCK RKD 800/2x40 Ringkerntransformator 2 x 115 V 2 x 40 V/AC 800 VA 10 A

Sedlbauer 858 255 Ringkerntransformator 1 x 230 V 2 x 12 V/AC 120 VA 5 A

Sedlbauer 858260 Ringkerntransformator 1 x 230 V 2 x 30 V/AC 160 VA 2.67 A

BLOCK RTE 160/2x12 Ringkerntransformator 160 VA 6.67 A

BLOCK RKD 40/2x15 Ringkerntransformator 2 x 115 V 2 x 15 V/AC 40 VA 1.33 A

Sedlbauer 858261 Ringkerntransformator 1 x 230 V 2 x 45 V/AC 300 VA 3.33 A

Sedlbauer 858741 Ringkerntransformator 1 x 230 V 2 x 30 V/AC 300 VA 5.00 A

Sedlbauer 859771 Ringkerntransformator 1 x 230 V 2 x 18 V/AC 80 VA 2.22 A

BLOCK RKD 300/2x24 Ringkerntransformator 2 x 115 V 2 x 24 V/AC 300 VA 6.25 A

BLOCK RKD 500/2x30 Ringkerntransformator 2 x 115 V 2 x 30 V/AC 500 VA 8.33 A

Sedlbauer 825024 Ringkerntransformator 1 x 230 V 2 x 6 V/AC 100 VA 8.33 A

BLOCK RTE 100/2x24 Ringkerntransformator 100 VA 2.08 A

Sedlbauer 858 257 Ringkerntransformator 1 x 230 V 2 x 30 V/AC 120 VA 2 A

BLOCK RKD 30/2x15 Ringkerntransformator 2 x 115 V 2 x 15 V/AC 30 VA 1 A

BLOCK RTE 300/2x24 Ringkerntransformator 300 VA 6.25 A

BLOCK RTE 100/2x12 Ringkerntransformator 100 VA 4.17 A

Bevestigingsschijven 60 mm 530 241 Sedlbauer

Sedlbauer 825028 Ringkerntransformator 1 x 230 V 2 x 18 V/AC 100 VA 2.78 A

BLOCK RTE 30/2x12 Ringkerntransformator 30 VA 1.25 A

BLOCK RTE 250/2x12 Ringkerntransformator 250 VA 10.4 A

Sedlbauer 825053 Ringkerntransformator 2 x 115 V 2 x 30 V/AC 300 VA 5 A

BLOCK RTE 500/2x24 Ringkerntransformator 500 VA 10.40 A

Sedlbauer 859761 Ringkerntransformator 1 x 230 V 1 x 11.50 V/AC 300 VA

BLOCK RTE 20/2x24 Ringkerntransformator 20 VA 417 mA

BLOCK RTE 120/2x12 Ringkerntransformator 120 VA 5 A

Sedlbauer 858 253 Ringkerntransformator 1 x 230 V 2 x 18 V/AC 50 VA 1.39 A

Sedlbauer 825025 Ringkerntransformator 1 x 230 V 2 x 9 V/AC 100 VA 5.56 A

BLOCK RTE 100/2x18 Ringkerntransformator 100 VA 2.78 A

BLOCK RKD 500/2x35 Ringkerntransformator 2 x 115 V 2 x 35 V/AC 500 VA 7.14 A

Sedlbauer 858 259 Ringkerntransformator 1 x 230 V 2 x 18 V/AC 160 VA 4.44 A

BLOCK RKD 80/2x24 Ringkerntransformator 2 x 115 V 2 x 24 V/AC 80 VA 1.67 A

BLOCK RTE 80/2x24 Ringkerntransformator 80 VA 1.67 A

BLOCK RKD 30/2x12 Ringkerntransformator 2 x 115 V 2 x 12 V/AC 30 VA 1.25 A

BLOCK RTE 120/2x24 Ringkerntransformator 120 VA 2.5 A

BLOCK RKD 15/2x15 Ringkerntransformator 2 x 115 V 2 x 15 V/AC 15 VA 500 mA

Bevestigingsschijven 75 mm 530 214 Sedlbauer

Sedlbauer 825073 Ringkerntransformator 2 x 115 V 2 x 115 V/AC 1000 VA 4.35 A
Talema 19262-P1S02 Ringkerntransformator 1 x 230 V 2 x 15 V 50 VA
Talema 19264-P1S02 Ringkerntransformator 1 x 230 V 2 x 22 V 50 VA

Talema 19860-P2S02 Ringkerntransformator 2 x 12 V 50 VA
Advies
Wat is een ringkerntransformator?
Transformatoren worden ook wel omvormer genoemd. Als elektrotechnische componenten worden transformatoren gebruikt om wisselspanningen te transformeren naar een lager of hoger spanningsniveau, of om een galvanische scheiding tot stand te brengen tussen de ingangs- en uitgangszijde.
Transformatoren bestaan uit twee of meer spoelen van koperdraad gewikkeld op een ijzeren of ferrietkern. Het aantal windingen van de primaire en secundaire wikkelingen bepaalt de verhouding van de ingangs- en uitgangsspanning. Bijvoorbeeld, als een transformator een wikkelverhouding van 20:1 heeft, zet hij een ingangsspanning van 230 volt om in 11,5 volt aan de uitgangszijde.
In tegenstelling tot conventioneel ontworpen transformatoren, waarbij de ijzeren kern bestaat uit een U- of E-vormig pakket van plaatmetaallaminaten, wordt in een ringkerntransformator een ringvormige kern gebruikt. Deze kern bestaat hetzij uit zacht magnetisch, ferritisch materiaal, dat door een sinter- of persprocédé in de gewenste vorm wordt gebracht, hetzij uit ringvormige stroken plaatstaal, die van elkaar geïsoleerd zijn. Vanwege de gesloten ringkern kunnen ringkerntransformatoren alleen met speciale machines worden gewikkeld.
In vergelijking met transformatoren van conventioneel ontwerp bieden ringkerntransformatoren een hele reeks voordelen: Hun vermogensdichtheid is groter, zodat een compactere en lichtere ringkerntransformator volstaat voor hetzelfde vermogen. Toroïdale transformatoren veroorzaken aanzienlijk minder zwervende magnetische velden, zijn minder gevoelig voor storende bromgeluiden en nemen aanzienlijk minder stroom op in onbelaste toestand. Zij veroorzaken echter relatief hoge stroompieken (inschakelstromen) tijdens het inschakelproces, omdat er geen luchtspleten zijn zoals bij transformatoren met U- of E-kernen.
Welke soorten ringkerntransformatoren zijn er?
Ringkerntrafo's zijn verkrijgbaar in diverse uitvoeringen, aangepast aan verschillende toepassingen. Naast verschillende wikkelverhoudingen voor alle gangbare spanningen, zijn er modellen met een overbrengingsverhouding van 1:1; zij dienen als scheidingstransformatoren. Transformatoren met een factor 2:1 of 1:2 passen apparaten aan voor werking op 115 volt wisselstroom naar een 230 volt net of omgekeerd. Vaak zijn er meerdere wikkelingen, zodat aan secundaire zijde verschillende spanningen uit één transformator kunnen worden gehaald en de transformator aan primaire zijde gelijkelijk op 115 en 230 volt netspanning kan worden gebruikt.
Voor laagspanningsverlichting worden transformatoren gebruikt met een aantal windingen van 20:1 (bij een netspanning van 230 V). Zij leveren 11,5 V aan de secundaire zijde voor halogeenlampen. Deze ringkerntransformatoren zijn ook verkrijgbaar ingekapseld in witte plastic bekers voor eenvoudige en onopvallende plafondmontage. Temperatuur- en overbelastingszekeringen kunnen worden geïntegreerd. De aansluitingen van ringkerntransformatoren zijn meestal uitgevoerd als vrije kabeleinden; speciale types kunnen ook worden voorzien van vaste aansluitstekkers, schroefklemmen of soldeerpennen. Net als conventionele transformatoren zijn ringkerntransformatoren verkrijgbaar in volledig ingekapselde versies.
Waar moet u op letten als u ringkerntransformatoren koopt?
Een hoog elektrisch rendement en lage nullastverliezen hebben een gunstig effect op de bedrijfskosten. Het volgende geldt: hoe krachtiger een ringkerntransformator is, des te opvallender zijn deze aspecten in de praktijk. Zeer hoogwaardige en efficiënte ringkerntransformatoren kunnen rendementen tot 98% behalen. Een zo hoog mogelijk rendement bespaart niet alleen energie, maar leidt ook tot minder warmteverlies en minder koeling.
Gedeeltelijk en vooral volledig ingekapselde ringkerntransformatoren zijn bijzonder stil met betrekking tot storende bromgeluiden bij werking op 50- of 60-Hertz-netwerken. Een potting compound dempt bovendien de minimale trillingen van de spoelwindingen, zodat de storende netbrom praktisch niet meer waarneembaar is.
Praktische tip voor het gebruik van ringkerntransformatoren
Gebruik, indien mogelijk, ringkerntransformatoren in het bereik van 50 tot 100% van hun nominaal vermogen. Hun efficiëntie is dan het beste. Grotere ringkerntransformatoren kunnen leiden tot ongewenste uitschakeling van vermogensschakelaars vanwege hun relatief hoge inschakelstromen. Dergelijke problemen kunnen worden opgelost door een transformator-schakelrelais aan te sluiten of anders met inschakelstroombegrenzers (NTC).
Veelgestelde vragen over ringkerntransformatoren
Waarom moet een ringkerntransformator voor 12 volt halogeenlampen zo mogelijk met zijn nominale vermogen worden belast?
De nullastspanning van transformatoren is aanzienlijk hoger dan de uitgangsspanning onder belasting. Laagbelaste transformatoren hebben dienovereenkomstig hogere uitgangsspanningen, die in de praktijk leiden tot een sterk verminderde levensduur van de lampen als gevolg van overspanning. Om dezelfde reden moeten defecte lampen altijd snel worden vervangen.
Waarom is de uitgangsspanning van een ringkern stabieler onder belasting?
De praktisch onbestaande luchtspleet leidt niet alleen tot een aanzienlijk lager zwervend magnetisch veld, maar zorgt ook voor een lagere impedantie. Onder belasting "knikt" de transformator dus niet zo sterk als een vergelijkbare transformator van conventioneel ontwerp.